Tag:phosphates

№12|2013

WASTEWATER TREATMENT

bbk 000000

UDC 628.34:66.081

Maiboroda A. B., Katraeva I. V., Kolpakov M. V.

Effluent polishing with the use of ultrafiltration

Summary

The results of investigating the removal of phosphate ions and suspended solids that enhance eutrophication of water bodies from biologically treated domestic wastewater after secondary settling tank are presented. Experimental studies of effluent polishing with the use of ultrafiltration technology in combination with coagulation were carried in the laboratory of the Nizhny Novgorod State University of Architecture and Civil Engineering. The aluminium hydroxychloride dosage of 20 mg/l as Al2O3 was used as a coagulant. Hollow-fiber module manufactured by Fazerkraft Russian Company with polyvinylidenefluoride was used for tangential ultrafiltration in cycle mode. The membrane module is a device with a cylindrical shell with a bunch of hollow fibers inside with porous walls. The impact of transmembrane pressure on the filtration process was investigated. It was found that the specific flow rate of permeate increases with the increase of transmembrane pressure within the range of 0.05–0.2 bar. The tests showed that 20-fold increasing the concentration of the suspension subject to treatment does not result in any significant decrease of permeate production of the membrane module. Increasing recycling rate (of tangential flow) results in the increase of permeate flow; however, on account of technical and economic aspects, the range of low recycle flow values is of most interest. The results of the studies showed that the suggested ultrafiltration technology provided for almost complete elimination of suspended solids (more than 93% treatment efficiency), 97% reduction of phosphates in wastewater, and reduction to 0.04 mg/l aluminium concentration in permeate.

Key words

, , , ,

 

№4|2013

ADVANCED TECHNOLOGIES AND EQUIPMENT

bbk 000000

ekotonUDC 628.334.5

Ponomarenko E. A., Pesin S. D., Melnik D. V.

EkoTON equipment for circular secondary settling tanks

Summary

The results of EkoTON Research and Production Company improving the design of sludge suction device for circular secondary settling tanks are presented. The reasons of sludge washout from the settling tanks and high moisture content of removed sludge are considered. Technical solutions on upgrading the equipment for wastewater treatment facilities and improving the operation factor of settling tanks are proposed. With that no rebuilding of either structural units of settling tanks or connected utilities is required.

Key words

, , , , , , ,

 

№4|2012

«TECHNOVOD–2012»

bbk 000000

UDC 628.16.081:661(24+48+63)

Gandurina L. V., Potapova L. V.

Precipitating capacity of AQUA-AURAT™30 coagulant in water treatment in the presence of calcium hydroxide

Summary

The results of experimental studies of simultaneous elimination of sulphates, phosphates and fluorides from water with AQUA-AURAT™30 aluminium polyoxychloride in the presence of calcium hydroxide are presented. It was shown that the standard concentration of sulphates and phosphates is ensured with the chemical dosage ratio 4.5 (as active СаО/Аl2О3) and рН 11. Fluoride concentration under the circumstances is decreasing from 11 to 2 mg/l. The standard fluoride concentration in treated water is ensured at рН 7.

Key words

, , , , , ,

 

№11|2011

МГСУ - 90 лет

bbk 000000

UDC 628.35:661.63

Zalyotova N. A.

Specific characteristics of phosphorus removal in biological wastewater treatment

Summary

It is shown that in using chemicals for deep phosphorus removal in biological wastewater treatment or effluent polishing one must take into account the effect of added metal ions on biological treatment process. A technique is suggested for estimating chemical consumption depending on the selected flow scheme of biological and chemical treatment; adjusting factors with account of this effect are given.

Key words

, , , , , , , ,

 

№9|2016

WASTEWATER TREATMENT

bbk 000000

UDC 628.345.1

Zalyotova N. A.

Phosphorus compounds in municipal wastewater

Summary

The analysis of the results of determining phosphorus compounds in wastewater at the treatment facilities is presented. In order to remove phosphorus compounds different methods of municipal wastewater treatment are used. The efficiency of eliminating some or other phosphorus forms depends on the technology used. The ratio of separate phosphorus forms in raw sewage differ much from effluent; therefore their impact on the water body also differs even if the discharged effluent quality is meeting the maximum permissible concentration of phosphates. Addition of chemical into wastewater provides for the fast and reliable removal of phosphates. The efficient reduction of total phosphorus and phosphates occurs only under the combination of biological and chemical wastewater treatment, or under the use of the modified biological treatment with alternating aerobic and anaerobic conditions of activated sludge retention.

Key words

, , , , ,

 

№5|2012

WASTEWATER TREATMENT

bbk 000000

UDC 628.35 (211)

Kounakhovich A. A.

Domestic wastewater advanced treatment unit for the use in the settlements of the northern climatic region

Summary

The experts from «Engineering Equipment Trading House» developed and mastered manufacturing of the treatment facilities for domestic wastewater and industrial wastes close by composition to domestic wastewater for the camps in the northern construction climatic region. Tver-C units for advanced treatment of domestic wastewater provide for the comprehensive solution to ensure efficient operation of the treatment facilities in rigorous climate northern areas.

Key words

, , , , , , , , , ,

 

vstmag engfree 200x100 2

mvkniipr ru

Российская ассоциация водоснабжения и водоотведения

Конференция итог

ecw20 200 300